Quality

Quality Assurance Systems


Are being followed in accordance with ISO 9001: 2008 / PED QMS & API Spec Q1 standard requirements to achieve a high degree of efficiency in operations. Constant efforts are made for the improvement of techniques, keeping in pace with the latest technology and standards. The inspection and testing activities are carried out in different stages of manufacturing to ensure the product compliance to standard and legal requirements.

Quality Policy :


  • We design, manufacture, market, sale & service quality valves to the entire satisfaction of the customer.
  • Continual Improvement in the product, process & the system shall be our core objective.

List Of Testing Equipments (In House Facilities)
Equipment Make & Specs Procedure ref Acceptance ref
  Chemical Properties    
Spectrometer Spectro Lab - 18 Elements Applicable Std Applicable Std
  Machanical Properties    
Hardness Testing Machine
Universal Testing Machine
Impact Testing Machine
OPTO-Fine Instruments
Venus Instruments-40
Venus Instruments-300J
ASTM A 370
ASTM A 370
ASTM A 370
Applicable Std
Applicable Std
Applicable Std
  Non - Destructive Testing    
Dye Penetrant Testing
Magnetic Particle Testing
Radiography Testing
Ultrasonic Testing
Mass Spectrometer Leak Detector
Magnaflux - Solvent Removal
Magnaflux - Pro Method
lr.192
Modsonic
Alcatel ASM 142
ASME Sec V Artical 6
ASME Sec V Artical 7
ASME Sec V Artical 2
ASME Sec V Artical 5
ASME Sec V Artical 10
ASME B 16.34
ASME B 16.34
ASME B 16.34
ASME 609/388
Applicable Spec
  Functional Testing    
Hydro Testing
Pneumatic Testing (Fluid: Air & Nitrogen)
Endurance Testing
Cycle Life of Bellows
RD Hydro Trust 15-90
RD Hydro Trust 15-90
In House Set Up
In House Set Up
API 598
API 598
In House procedure
MSS-SP-117
API 598
API 598
Applicable Spec
MSS-SP-117
  Visual Examination    
Visual Not Applicable ASME Sec V Article 9 MSS SP 55(ex)
Can also conduct the following Test
 IGC Testing For Stainless Steel
 Positive Material Identification
 Wet Analysis
 Seismic Testing